5K30.20 Dissectible Transformer
Concepts
Magnetic induction, transformers
Overview
This is a transformer with swappable secondary coils, which all step down from the wall outlet 120 VRMS.
Details
Equipment
- [1] Dissectible transformer with 800-turn primary coil
- [1] 40-turn coil
- [1] 80-turn coil
- [1] 200-turn coil
- [1] Multimeter & leads
Classroom Assembly
- Assemble the transformer with the desired secondary coil.
- Attach the multimeter to the secondary coil.
- Set the multimeter to AC volts at an appropriate scale.
Important Notes
- Some of the secondary coils are hard to attach to and remove from the iron core. Try not to hurt yourself doing this.
Script
- Turn on the multimeter.
- Plug in the transformer.
- Note the voltage across the secondary coil.
- Change the secondary coil and repeat 1–3 as required.
- Unplug the transformer.
Additional Resources
References
- PIRA 5K30.20
Disclaimer
- Don't attempt this at home!